Template:CephTroubleshooting: Difference between revisions

From OSNEXUS Online Documentation Site
Jump to navigation Jump to search
Line 7: Line 7:


* Replace failed drive and return hardware RAID5 to normal operational status
* Replace failed drive and return hardware RAID5 to normal operational status
== Storage Pool / RAID LUN Failure ==
* Identify cause of storage loss
** If correctable, restore connectivity/availability of underlying storage and import pool.  OSD will return to normal status automatically
** If not correctable, remove the OSD from the Ceph configuration.  Provide new storage and use the steps described in the Management and Operations section to create a new OSD (and Journal if necessary).


== Node Connectivity Issues ==
== Node Connectivity Issues ==

Revision as of 17:45, 4 June 2019

Troubleshooting

The following guide will provide an outline of steps to take when encountering issues with Scale-out SAN and Object Storage using Ceph in a QuantaStor environment.

Hardware Disk Failure

  • Replace failed drive and return hardware RAID5 to normal operational status

Node Connectivity Issues

  • Verify networking hardware infrastructure is correct and all cabling valid
  • Verify that node network configuration is correct under System Management
    • Note that all nodes must share networks on the same network port (ie, All nodes should have 10.0.0.0/16 on ethX, 192.168.0.0/16 on ethY)

Ceph will automatically restore OSD status and rebalance data once network status has been successfully restored.

Node Failure and Replacement

In the event a node has completely failed (due to hardware failure, decomissioning, or other action), the node should be removed from the Ceph cluster.

A new node can then be added to the cluster (if desired or necessary).

See the Management and Operations section for details on Removing and Adding a node to a Ceph cluster.