Hardware Disk Mark Hotspare: Difference between revisions

From OSNEXUS Online Documentation Site
Jump to navigation Jump to search
mNo edit summary
mNo edit summary
Line 1: Line 1:
{{DISPLAYTITLE:Marking/Unmarking Hot-spares for Hardware RAID Units}}
{{DISPLAYTITLE:Marking/Unmarking Hot-spares for Hardware RAID Units}}
Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose ''Mark/Unmark Hot-spare''.  Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller.  As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units.  Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.  
Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose ''Mark/Unmark Hot-spare''.  Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller.  As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units.  Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.  
'''Navigation:''' Storage Management --> Hardware Controllers & Enclosures --> Select/Expand Appliance --> Select/Expand Controller --> Mark/Un-mark Hot-spare ''(rightclick)''


[[File:qs_mark_hwdisk_hotspare.png]]
[[File:qs_mark_hwdisk_hotspare.png]]


'''Navigation:''' Storage Management -> Hardware Controllers & Enclosures -> Select/Expand Appliance -> Select/Expand Controller -> Right-click & select '''Mark/Un-mark Hot-spare'''


{{Template:ReturnToWebGuide}}
{{Template:ReturnToWebGuide}}
[[Category:QuantaStor4]]
[[Category:QuantaStor4]]
[[Category:WebUI Dialog]]
[[Category:WebUI Dialog]]

Revision as of 18:16, 23 July 2018

Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose Mark/Unmark Hot-spare. Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller. As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units. Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.

Navigation: Storage Management --> Hardware Controllers & Enclosures --> Select/Expand Appliance --> Select/Expand Controller --> Mark/Un-mark Hot-spare (rightclick)


Return to the QuantaStor Web Admin Guide