+ | Communicates with the hardware RAID/HBA controller to toggle marking/un-marking of the specified disk as a hot-spare. Disks marked as hot-spares within a RAID controller can only be used as a hot-spare for RAID units created by that controller. As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units. Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply. | ||
[[File:qs_mark_hwdisk_hotspare.png]] | [[File:qs_mark_hwdisk_hotspare.png]] |
Revision as of 16:17, 27 February 2017
Communicates with the hardware RAID/HBA controller to toggle marking/un-marking of the specified disk as a hot-spare. Disks marked as hot-spares within a RAID controller can only be used as a hot-spare for RAID units created by that controller. As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units. Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.
Navigation: Storage Management -> Hardware Controllers & Enclosures -> Select/Expand Appliance -> Select/Expand Controller -> Right-click on Disk