Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose ''Mark/Unmark Hot-spare''.  Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller.  As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units.  Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.  
Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose ''Mark/Unmark Hot-spare''.  Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller.  As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units.  Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.  


'''Navigation:''' Storage Management --> Hardware Controllers & Enclosures --> Select/Expand Appliance --> Select/Expand Controller --> Mark/Un-mark Hot-spare ''(rightclick)''


[[File:qs_mark_hwdisk_hotspare.png]]
[[File:qs_mark_hwdisk_hotspare.png]]

Revision as of 18:17, 23 July 2018

Hardware RAID units require hot-spares to be configured within the RAID controller. To toggle marking/un-marking of the specified disk as a hot-spare simply right-click on a disk within the controller and choose Mark/Unmark Hot-spare. Note that devices marked as hot-spares within a RAID controller can only be used as a hot-spares for RAID units managed by that specific controller. As such if a system has two or more RAID controllers each one will need one or more disks marked as hot-spares in order to get automatic healing of RAID units. Systems using fault-tolerant software RAID at the Storage Pool level using HBAs have no requirement to specify hardware RAID hot-spares and in such cases this section does not apply.